Call us now +04-261-8919







Product Details


Details



Addressable Control Panel

Product Type : Others Products
Product Category : Addressable Control Fire Alarm System
Product Model : SME-WMP26-EN
Product Status : Non Discontinued


Downloads



Product Features

  • the default standard system consists of 2-loops, and it could be expanded to 6-loops
  • Supports 125 addressable devices per loop.
  • Supports wireless detection devices.
  • Automatic device detection on start-up.
  • Automatic device type-code verification.
  • 128 configurable zones.
  • 32 zone fire alarm LED indicators.
  • 32 addressable audio/visual alarm devices per loop.
  • Manual activation of alarm devices.
  • Configurable timer to delay fire alarm condition output activation.
  • Supervised auxiliary DC 24 V output.
  • 4 Access Levels.
  • Configurable day/night mode.
  • Backlit LCD providing 4 rows of 40 characters.
  • Supports up to 16 repeater panels.
  • 3000 event history log.
  • Easy installation.

Product Specifications

Power Supply

Operating Voltage AC (100 ~ 260) V / 50/60 Hz
Mains Supply Current Limit 1.5 A / AC 230 V
Mains Supply Fuse 4 A / AC 250 V slow blow (20 mm)
Mains Supply Fault Threshold Voltage ≤ AC 60 V
Power Supply 4.3 A / DC 28.5 V
Quiescent Current 200 mA / DC 28.5 V
Maximum Continuous Output Current (Ia, Max) 1.4 A
Maximum Short-Duration Output Current (Ib, Max) 2.3 A
Standby Battery Maximum Capacity (2 × Dc 12 V) 7.2 Ah
Maximum Battery Current Draw at Maximum Operating Temperature 1.5 A
Battery Fuse 10 A resettable (electronic fuse)
Battery Fault Threshold Voltage < DC 20 V
Battery Fault Threshold Internal Resistance (Ri, Max) 0.5 Ω

Addressable Loops

Addressable Loops 2 ~ 6
Number Of Connected Devices Per Loop 125
Loop Current (Max) 400 mA
Loop Monitoring Open- and short-circuit

Audio/Visual Alarms

Configurable audio/visual alarm groups (max) 512
Conventional audio/visual alarm device driver 700 mA
Conventional audio/visual alarm end-offline resistor 10 kΩ
Alarm zone monitoring Open- and short-circuit
Alarm zone voltage (max) DC 29 V
Alarm zone fuse 1.1 A resettable (electronic fuse)

Wireless Transmission Path

Maximum Number Of Wireless Nodes (Per Loop) 62
Wireless Node ID Range 1 ~ 124
Wireless Radio Interconnection Operating Frequencies 433 MHz, 868 MHz, 915 MHz
Number Of Selectable Radio Channels 125

Ancillary Outputs

Number of programmable output relays 2
Ancillary fire C/O relay 2 x (1.0 A / DC 30 V / 1 A / AC 240 V)
Ancillary fault N/C relay 1.0 A / DC 30 V / 1 A / AC 240 V
Auxiliary supply DC (19 ~ 30) V / 200 mA

Miscellaneous

Event history log 3000 events
Number of networked repeaters 16
Terminal wiring (0.4 ~ 2.5) mm2
Operating temperature (-5 ~ +40) °C
Operating humidity (0 ~ 95) % RH, non-condensing
Storage temperature (-25 ~ +80) °C
Storage humidity (0 ~ 98) % RH, non-condensing
Dimensions (h × w × d) (485 × 465 × 155) mm